Location and Frequency
Location |
Frequency |
|
---|---|---|
Inside of the scanner (ADF) |
Brake roller |
Every 5,000 sheets |
Pick roller |
||
Feed roller |
||
Eject roller |
||
Glass |
||
Ultrasonic sensor |
||
Document sensor |
||
Inside of the scanner (Flatbed) [fi-8290/fi-8270/fi-8250/fi-8250U] |
Document pad |
|
Document bed |
||
Plastic frame |
The inside of the scanner (ADF) needs to be cleaned regularly for every certain number of sheets scanned. The scanner records the number of sheets scanned so that you can check the number of sheets scanned after you cleaned it last.
For fi-8190/fi-8290/fi-8170/fi-8270
Use one of the following methods to check the number of sheets that have been scanned.
You can select [5: Consumable counters] from the [Settings Menu] screen on the operator panel to check the number of sheets that have been scanned.
For details, refer to How to Use Settings Menu.
You can check the number of sheets that have been scanned in the Software Operation Panel.
For details, refer to Checking the Sheet Counters.
For fi-8150/fi-8250/fi-8150U/fi-8250U
You can check the number of sheets that have been scanned in the Software Operation Panel.
For details, refer to Checking the Sheet Counters.
Cleaning cycles may vary depending on the condition of the documents. Also, cleaning must be performed more frequently when the following types of documents are scanned:
Smooth-faced documents such as coated paper
Documents with printed text/graphics that almost cover the entire surface
Chemically-treated documents such as carbonless paper
Documents containing a large amount of calcium carbonate
Documents written in lead pencil
Documents on which the toner is not sufficiently fused